NAVAC NMV1 Micron Vacuum Gauge – Pirani Sensor, 0–75,000 Microns, 1/4″ Flare, Leak Alarm Buzzer

$132.60

NAVAC NMV1 micron gauge with Pirani sensor, 0–75,000 microns range, 1/4″ flare connection, and 90 dB leak alarm for dependable HVAC evacuation verification.

Availability: 3 in stock SKU: NMV1

Description

The NAVAC NMV1 Micron Vacuum Gauge is built to accurately monitor evacuation depth during HVAC/R service so you can confirm when a system is dry, tight, and ready to charge. Using a Pirani vacuum sensor, the NMV1 precisely measures deep vacuum levels to help verify proper moisture removal, detect leaks, and evaluate vacuum pump performance.

For daily field use, the gauge provides a clear digital display and supports multiple vacuum units including Microns, Pa, mBar and mmHg, so technicians can work in the format they prefer. The NMV1 connects via a standard 1/4″ flare fitting, making it easy to install directly on the system or through an access tee.

To help catch problems early, it includes an audible 90 dB alarm that triggers when vacuum rises above the programmed threshold (and it flashes the backlight during the alarm period), making leaks or moisture boil-off events easier to notice while you’re working. It also includes automatic shutoff behavior when there are no changes over a set time window, helping conserve battery.

Additional information

Weight 0.29 lbs
Dimensions 7.5 × 4.5 × 2.5 in
Brand

NAVAC

Model

NMV1

Sensor Type

Pirani sensor

Vacuum Range

0–75,000 microns (also shown as 0–75.000 mmHg / 0–100.00 mBar / 0–10,000 Pa)

Accuracy

15–750 microns: ±5% of reading (at 68°F)

Resolution

Listed in manual (micron resolution changes by range)

Connection

1/4" flare

Alarm

90 dB (10 seconds)

Operating Temp

32–122°F (0–50°C)

Max Overload Pressure

14 psi (0.1 MPa)

Power

3×AA batteries

Reviews

There are no reviews yet.


Be the first to review “NAVAC NMV1 Micron Vacuum Gauge – Pirani Sensor, 0–75,000 Microns, 1/4″ Flare, Leak Alarm Buzzer”